Verify Joists
have Adequate
Bearing
B3i
I-JOIST END OVER INTERIOR SUPPORT
with Continuous Rim
LP LSL, LP LVL or LP Rim may
be used.
Place nail 1-1/2" min. from end of
I-Joist. If nails are close to edge
of plate, drive at an angle to
reduce splitting.
8d nail at 6" o.c.
Fasten rim board to each floor
I-Joist using one 8d nail or
10d box nail per flange
(when used for shear transfer
nail to bearing plate with same
nailing schedule as decking)