Situated under roof eaves, soffit is a smaller exterior feature that can be easy to overlook but is crucial for adequate airflow. LP® SmartSide® Vented Soffit provides continuous ventilation for the roof, and it’s made with the same durable materials and and boasts the same great aesthetics as LP SmartSide Trim & Siding. Let’s take a look at exactly what vented soffit is, the important role it plays on a home, and how to build with it. 

Are Vented Soffits Necessary?

For some overhang areas closed soffit works just fine, but for others—especially those that lead to your attic or are particularly large—vented soffit is recommended for proper ventilation. Be sure to check local codes to see what is allowed in your area as it may vary from build to build.

While vented soffit isn’t the only way to provide airflow throughout from eaves to your attic, it is a great alternative to metal vents that can distract from the exterior aesthetics. LP SmartSide Vented Soffit is designed to promote continuous airflow throughout a home’s roof and attic while remaining cohesive with the rest of the exterior. 

How Many Soffit Vents Do You Need?

The first step to determining how many soffit vents you need is to check your local building code requirements. If there are no distinct requirements for the amount of soffit vents, the general rule is to split your soffit vents between your attic and under eave soffit vent and install one square foot of soffit vents for every 150 square feet. 

Can you have too many soffit vents?

Generally speaking, more ventilation for your roof is a good thing. According to HVAC Seer, the key to gauging the right amount of vented soffit is making sure that the intake vent area is equal to or more than the exhaust vent area. Once you reach the minimum ventilation amount, you may add more soffit vents as long as you monitor the exhaust area. 

20_900px-wide

Do You Need Soffit Vents with Gable Vents?

While it isn’t mandatory to use both gable and soffit vents, it is highly recommended for adequate ventilation to help reduce moisture buildup. Since gable vents and soffit vents are positioned at different heights on a structure, utilizing both will provide continuous airflow. 

How to Install Soffit Vents

LP SmartSide Vented Soffit should be applied to the eaves over framing that spans a maximum of 24 inches on center. All ends and edges must be supported by solid 2x4-inch or larger framing. Be sure to layout and install vented soffit in a manner that eliminates the need to cut through the vents. 

When positioning your soffit, be sure that the vents are away from the wall and ensure all ends and edges land on studs. 

Fasten the soffit around the perimeter a maximum of every 6 inches and every 12 inches at intermediate supports. 

How to Install Soffit at Corners

For vented corners with square-cut ends, run vented soffit all the way to the corner and butt the straight-cut edges of the soffit without cutting through the vents. When installing soffit at corners, make sure that the vents do not land closer than three inches from the end or corner and avoid making diagonal cuts through the vents.

For more installation details, view the LP SmartSide Soffit installation instructions

How far apart should soffit vents be?

LP SmartSide vented soffit comes in 16-foot lengths, which helps make it easier to install and can reduce the number of visible seams. Each 16-foot piece of LP SmartSide Vented Soffit is equipped with 16 vents spaced four inches apart, each with 10 eight-inch-long openings and can be applied to the eaves on the entire perimeter of a house. Refer to the installation instructions for further guidance.

cm302844-edit-r2-3-_900px-wide

Continuous Soffit Vents

Continuous soffit vents are a type of soffit ventilation, usually perforated, that are typically used on narrow eaves. They perform similarly to vented soffit and have the same goal of increasing airflow; however, they often lack the aesthetic value that comes with vented soffit and are less suitable for larger eaves.

LP SmartSide Vented Soffit is made with the same durable materials as the other products in the LP SmartSide collection and is designed to create a cohesive look when used with LP® SmartSide® and LP® SmartSide® ExpertFinish® Trim & Siding products.

Curious about how to include vented soffit on your next build? Browse through our collection of images to find ideas for your project.

Continue Reading

Business Solutions

4 min

Q&A: How Home Orientation Impacts Continuous Insulation

There’s a lot to consider when it comes to building an energy-efficient home for your clients and the many nuances that change with each build—including its orientation to the sun. We sat down with Neil Freidberg, Building Science Manager at LP, to unpack the impact of home orientation on continuous insulation needs. 

Continue Reading

Resiliency Solutions

5 min
HOW A RADIANT BARRIER CAN IMPROVE BURIED DUCT PERFORMANCE

One of the questions LP® Building Solutions gets from builders often is about burying ducts in attic insulation and whether combining radiant barrier sheathing with blown insulation over ductwork can benefit homeowners. As with most technical situations, the outcome depends on a nuanced approach. Let’s dig in and explore this question. 

Sustainability Solutions

8 min
How to Drive Effective Communication and Collaboration on the Jobsite

Every jobsite has a ton of moving parts, from product shipments, supplies, and schedules to subcontractors and homeowners. It’s no wonder that many project teams can struggle to maintain quality jobsite communication and collaboration throughout the building process. And when communication slips, construction companies inevitably deal with costly errors, inefficient workflows, delayed projects, or wasted time, leaving clients and the team frustrated.

Sustainability Solutions

6 min
Carbon Negative, Future Positive: LP® Structural Solutions Portfolio Releases Environmental Product Declarations

In an era where environmental responsibility is paramount, we are proud to announce a remarkable achievement: the LP® Structural Solutions portfolio has been officially designated as carbon negative. This milestone is a testament to our unwavering commitment to redefining construction materials for the better with a focus on sustainability, resiliency and groundbreaking advancements.